Fanuc Power Mate i-D/H Operation Maintenance Handbook

9. ERROR CODE LIST
325
Message Contents and solution
ER21 MESSAGE
DATA ERROR
Editing the message data was interrupted by the power off
or the switch to the CNC screen by the function key etc.
Please edit message data once on PMC.
Or, please input message data again.
ER22 PROGRAM
NOTHING
There is no sequence program
ER23 PLEASE TURN
OFF POWER
There is a change in setting LADDER MAX AREA SIZE
etc.
Please restart the system to make the change effective.
ER25 SOFTWARE
VERSION ERROR
(PMCAOPT)
The PMCSB management software editions are incon-
sistent.
Contact FANUC.
ER26 SOFTWARE
VERSION ERROR
(PMCAOPT)
The PMCSB management software cannot be initial-
ized.
Contact FANUC.
ER33 SLC ERROR The LSI for I/O Link is defective.
Please exchange the base PC board.
ER34 SLC ERROR
(xx)
The communication with the DI/DO units of the xx group
failed.
Please confirm the connection of the cable connected to
the DI/DO units of the xx group.
Please confirm whether the DI/DO units turned on earlier
than CNC and
PMC. Or, please exchange the module of PMC engine on
the DI/DO units of the xx group
ER35 TOO MUCH
OUTPUT DATA IN
GROUP (xx)
The number of the output data in the xx group exceeded
the max. The data, which exceed 32 bytes, become inef-
fective.
Please refer to the following for the number of the data for
each group.
FANUC I/O UnitMODEL A connecting and mainte-
nance manual (B–61813E)
FANUC I/O UnitMODEL B connecting manu-
al”(B–62163E)
ER36 TOO MUCH
INPUT DATA IN
GROUP (xx)
The number of the input data in the xx group exceeded the
max. The data, which exceed 32 bytes, become ineffec-
tive.
Please refer to the following for the number of the data for
each group.
FANUC I/O UnitMODEL A connecting and mainte-
nance manual (B–61813E)
FANUC I/O UnitMODEL B connecting manu-
al”(B–62163E)
ER38 MAX SETTING
OUTPUT DATA OVER
(xx)
The assignment data for a group exceeds 128 bytes.
(The assignment data of output side of xx group or later
become ineffective.)
Please reduce the assignment data to 128 bytes or less
for the number of the output data of each group.
ER39 MAX SETTING
INPUT DATA OVER
(xx)
The assignment data for a group exceeds 128 bytes.
(The assignment data of input side of xx group or later be-
come infective.)
Please reduce the assignment data to 128 bytes or less
for the number of the input data of each goup.
*When ER00 to ER26 occur, sequence program is not available.

Leave a Reply