Message Contents and solution
WN03 ABORT
NC–WINDOW/EXIN
LADDER was stopped while CNC and PMC were commu-
nicating.
The functional instruction WINDR, WINDW, EXIN,
DISPB, and etc. may not work normally.
When restarting the system, this alarm will be released.
Execute the sequence program(Press RUN key) after
confirming whether there is a problem in LADDER or not.
WN05 PMC TYPE NO
CONVERSION
A ladder program for the PMCSA3/SA5 was transferred
to the PMC–SB5.
Correct the ladder type.
WN07 LADDER SP
ERROR (STACK)
When functional instruction CALL(SUB65) or CAL-
LU(SUB66) was executed, the stack of the LADDER
overflowed.
Please reduce the nesting of the subprogram to 8 or less.
(2) System alarm messages (PMC)
Message Contents and solution
1 PC004 CPU ERR
xxxxxxxx:yyyyyyyy
PC006 CPU ERR
xxxxxxxx:yyyyyyyy
PC009 CPU ERR
xxxxxxxx:yyyyyyyy
PC010 CPU ERR
xxxxxxxx:yyyyyyyy
A CPU error occurred in the PMC.
xxxxxxxx and yyyyyyyy indicate internal error code.
If this error occurs, the base PC board may be faulty.
Replace the base PC board, then check whether the
error recurs. If the error still occurs even after the re-
placement of the motherboard, report the conditions
under which the error occurred (system configura-
tion, operation, time and frequency of error occur-
rences, etc.) to FANUC.
2 PC030 RAM PARITY
aa:bb
A RAM parity error occurred in the PMC.
aa and bb indicate internal error code.
If this error occurs, the base PC board may be faulty.
Replace the base PC board, then check whether the
error recurs. If the error still occurs even after the re-
placement of the motherboard, report the conditions
under which the error occurred (system configura-
tion, operation, time and frequency of error occur-
rences, etc.) and the indicated internal error code to
FANUC.