Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
328
(3) Alarm messages (For EDIT)
Message
Contents and solution
ADDRESS BIT
NOTHING
The address of the relay/coil is not set.
FUNCTION NOT
FOUND
There is no functional instruction of the input number.
COM FUNCTION
MISSING
The funcitonal instruction COM (SUB29) is not correctly
dealt with.
Correspondence of COM and COME (SUB29) is incor-
rect.
Or, the number of coil controlled by COM is specified by
the model which the number cannot be specified.
EDIT BUFFER OVER There in no empty area of the buffer for the editing.
Please reduce NET under editing.
END FUNCTION
MISSING
Functional instruction END1,END2,END3 and END do
not exist. Or, there are error net in END1,END2,END3,
END.
Or, order of END1,END2,END3, and END is not correct.
ERROR NET FOUND There is an error net.
ILLEGAL FUNCTION
NO.
The wrong number of the functional instruction is
searched.
FUNCTION LINE
ILLEGAL
The functional instruction is not correctly connected.
HORIZONTAL LINE
ILLEGAL
The horizontal line of the net is not connected.
ILLEGAL NET
CLEARED
Because the power had been turn off while editing LAD-
DER, some net under editing was cleared.
ILLEGAL OPERATION Operation is not correct.
The value is not specified and only INPUT key was
pushed.
The address data is not correctly inputted.
Because the space to display the instruction on screen is
not enough, the functional instruction cannot be made.
SYMBOL
UNDEFINED
The symbol which was inputted is not defined.
INPUT INVALID There is an incorrect input data.
Non–numerical value was inputted with COPY, INSLIN,
C–UP,C–DOWN etc.
The input address was specified for write coil.
An illegal character was specified for the data table.
NET TOO LARGE The input net is larger than the editing buffer.
Please reduce the net under editing.
JUMP FUNCTION
MISSING
The functional instruction JMP(SUB10) is not correctly
dealt with.
Correspondence of JMP and JMPE(SUB30) is incorrect.
The number of coil to jump is specified by the model which
the number of coil cannot specified. (It is possible to spec-
ify the coil number only on PMC–SB/SC.)
LADDER BROKEN LADDER is broken.
LADDER ILLEGAL There is an incorrect LADDER.
IMPOSSIBLE WRITE You try to edit sequence program on the FROM.
OBJECT BUFFER
OVER
The sequence program area was filled.
Please reduce the LADDER.