9. ERROR CODE LIST
329
Message Contents and solution
PARAMETER
NOTHING
There is no parameter of the functional instruction.
PLEASE COMPLETE
NET
The error net was found in LADDER.
After correcting the error net, please continue operating.
PLEASE KEY IN SUB
NO.
Please input the number of the functional instruction.
If you do not input the functional instruction, please push
soft key “FUNC” again.
PROGRAM MODULE
NOTHING
You tried to edit though there was neither RAM for debug-
ging nor ROM for sequence program.
RELAY COIL FORBIT There is an unnecessary relay or coil.
RELAY OR COIL
NOTHING
The relay or the coil does not suffice.
PLEASE CLEAR ALL It is impossible to recover the sequence program.
Please clear the all data.
SYMBOL DATA
DUPLICATE
The same symbol name is defined in other place.
COMMENT DATA
OVERFLOW
The comment data area was filled.
Please reduce the number of the commnet.
SYMBOL DATA
OVERFLOW
The symbol data area was filled.
Please reduce the number of the symbol.
VERTICAL LINE
ILLEGAL
There is an incorrect vertical line of the net.
MESSAGE DATA
OVERFLOW
The message data area was filled.
Please reduce the number of the message.
1ST LEVEL
EXECUTE TIME
OVER
The 1st level of LADDER is too large to complete execu-
tion in time.
Please reduce the 1st level of LADDER.
PARA NO. RANGE
ERR: MACHINE
INSTRUCTION NAME
The specified machine instruction parameter number is
out of the valid range.
Specify a valid parameter number.
PARA NO.
DUPLICATE:
MACHINE
INSTRUCTION NAME
EXIT?
There is a duplicate machine instruction parameter num-
ber.
If the duplicate parameter number does any harm,
change it to an unused number.