Fanuc Power Mate i-D/H Operation Maintenance Handbook

10. PMC
347
10.2.3 Alarm screen (ALARM)
Display of an alarm when an alarm occured in PMC program.
TITLE
[][][][][]
STATUS ALARM TRACE
PMC ALARM MESSAGE
ALARM NOTHING
MONIT RUN
10.2.4 Trace screen (TRACE)
Record the signal status to the trace memory when the specified signal is
changed.
(1) Trace parameter screen (TRCPRM)
T.DISP
[][][][][]
EXEC
PMC SIGNAL TRACE
MONIT RUN
TRACE MODE :
(0:1BYTE/1:2BYTE/2:WORD)
1ST TRACE ADDRESS CONDITION
ADDRESS TYPE : (0:PMC/1:PHY)
ADDRESS :
MASK DATA
2ND TRACE ADDRESS CONDITION
ADDRESS TYPE : (0:PMC/1:PHY)
ADDRESS :
MASK DATA :
(a) TRACE MODE: Select the trace mode.
0= 1 byte address signal trace
1= Independent 2 byte address signal trace
2= Continuous 2 byte address signal trace
(b) ADDRESS TYPE: 0= Set the trace address by PMC address
1= Set the trace address by physical
address (Using mainly by C language)
(c) ADDRESS : Set the trace address
(d) MASK DATA : Specify the trace bit by hexadecimal code.
For example, set the “E1” when trace the bit
7, 6, 5 and 0. Not execute the tracing when
the bit 4, 3, 2 and 1 is changed, but, the signal
status should recorded at tracing time.
(e.g) #7 #6 #5 #4 #3 #2 #1 #0
11100001:E1