Fanuc Power Mate i-D/H Operation Maintenance Handbook

10. PMC
349
10.2.6 Signal waveform display function screen (ANALYS)
(Memory card for ladder diagram editing is necessary)
(1) Parameter setting screen (1st page)
SCOPE
[][][][][]
DELETE INIT ADDRESS
PMC SIGNAL ANALISYS(PARAM)
MONIT STOP
SAMPLING TIME : 10(110 SEC)
TRIGGER ADDRESS : G0007.2
CONDITON : 0
(0:START 1:TRIGGERON 2:TRIGGER–OFF)
TRIGGER MODE : 0
(0:AFTER 1:ABOUT 2:BEFORE 3:ONLY)
SAMPLE TIME: Set the sampling time.
TRIGGER ADDRESS: Specify the trigger address when execute the
record by trigger.
CONDITION: Set the recording start condition.
0: Execute by [START] soft key.
1: Press [START] soft key than execute a
rising edge of trigger signal.
2: Press [START] soft key than execute a
fall edge of trigger signal.
TRIGGER MODE: Set the trigger mode.
0: Record the PMC signal AFTER trigger
signal.
1: Record the PMC signal AROUND trigger
signal.
2: Record the PMC signal BEFORE trigger
signal.
3: Record the PMC signal ONLY trigger
signal be formed.
(2) Parameter setting screen (2nd page)
SCOPE
[][][][][]
DELETE INIT ADRESS
PMC SIGNAL ANALISYS (PARAM)
SIGNAL ADDRESS
1 : X0000.0 9 : Y0000.0
2 : X0000.1 10 : R0000.1
3 : X0002.0 11 :
4 : X0005.0 12 :
5 : 13 :
6 : 14 :
7 : 15 :
8 : 16 :
MONIT STOP
Specify
16 kinds
recording
signals