Fanuc Power Mate i-D/H Operation Maintenance Handbook

10. PMC
357
10.4 Input/Output of PMC Data
10.4.1 Start of the built-in type PMC programmer
When the PMC data are input/output with I/O device unit via reader/puncher
interface, the built-in type PMC programmer should starts by as following
operation.
: As following operation is not required when the data set from MDI.
1 Select the PMC screen
Press
SYSTEM
key and press [PMC] softkey.
2 Confirm to the built-in type PMC programmer is running.
PMC CONTROL SYSTEM MENU
SELECT ONE OF FOLLOWING SOFT KEYS
PMCLAD : DYNAMIC LADDER DISPLAY
PMCDGN : DIAGNOSIS FUNCTION
PMCPRM : PARAMETER (T/C/K/D)
RUN/STOP : RUN/STOP SEQUENCE PROGRAM
EDIT : EDIT SEQUENCE PROGRAM
I/O : I/O SEQUENCE PROGRAM
SYSPRM : SYSTEM PARAMETER
MONIT : PMC MONITOR
PMCLAD
[][][][][]
PMCDGN PMCPRM
MONIT RUN
parts are displayed, starts of the built-in type PMC programmer.
The card editor is not used but it has PMC-SB system. This case,
[RUN/STOP] and [I/O] function can used but editing of sequence
program is impossible.
3 Keep relay K17.1 (K900.1 for the SB6) should set to “1” if the built-in type
PMC programmer is not start yet.
10.4.2 Input/output method
1 Press key in the initial menu screen, then display to [I/O] softkey.
2 Display next screen
EXEC
[][][][][]
CANCEL (NO.)
MONIT RUN
PMC I/O PROGRAM
CHANNEL = 1
DEVICE = HOST
FUNCTION =
DATA KIND =