Fanuc Power Mate i-D/H Operation Maintenance Handbook

3
1
4
5
6
7
8
9
10
2
20
1.2.6 Displaying the program list
(1) Press soft key [LIB].
(a) When parameter NAM (bit 0 of No. 3107) = 0
PRGRM
[][][][][]
LIB C.A.P. (OPRT)
PROGRAM DIRECTORY O0001 N00010
PROGRAM (NUM.) MEMORY (CHAR.)
USED: 60 3321
FREE: 3 429
O0240 (SHAFT XSF301 ) : ( )
O0010 O0001 O0003 O0002 O0555 O0999
O0062 O0004 O0005 O1111 O0969 O6666
O0021 O1234 O0588 O0020 O0040
>_ S 0 T0000
EDIT **** *** *** 16:05:59
Memory
utilization
condition.
One–meter
paper tape
contains
about 400
characters.
Program numbers
(b) When parameter NAM (bit 0 of No. 3107) = 1
PRGRM
[][][][][]
LIB C.A.P. (OPRT)
PROGRAM (NUM.) MEMORY (CHAR.)
USED: 60 3321
FREE: 3 429
O0240 (SHAFT XSF301 ) : ( )
O0001 (MACRO–GCODE.MAIN)
O0002 (MACRO–GCODE.SUB1)
O0010 (TEST–PROGRAM.ARTHMETIC NO.1)
O0020 (TEST–PROGRAM.F10–MACRO)
O0040 (TEST–PROGRAM.OFFSET)
O0050
O0100 (INCH/MM CONVERT CHECK NO.1)
O0200 (MACRO–MCODE.MAIN)
>_
EDIT **** *** *** 16:05:59
PROGRAM DIRECTORY O0001 N00010
(2) Operation
Program number
Soft key [(OPRT)]
[BG–EDT] ³ Same as PRGRM
Program number
[O SRH]
O
[READ] [MERGE]
[STOP]
[CAN]
[EXEC]
O
Program number
[PUNCH]
[STOP]
[CAN]
O
[EXEC]
(3) Related parameters
Parameter NAM (No. 3107#0): Only program numbers are listed/
Program numbers and program
names are listed.
Parameter SOR (No. 3107#4): Programs are listed in the order of
registration/in the order of program
number.