Fanuc Power Mate i-D/H Operation Maintenance Handbook

Data is input and output via the FANUC I/O Link
to and from the Power Mate in group n (where n
= 0 to 15)
to to
3
1
4
5
6
7
8
9
10
2
22
(d) To output the program
Program number
Can be omitted when the
program is added to the
same file.
[PUNCH]
[CAN]
[EXEC]
File number [F SET]
[O SET]
To specify all the
programs, enter
“–9999”
(e) To delete the program
File number
[F SET][DELETE] [CAN]
[EXEC]
File name
[F NAME] [CAN]
[EXEC]
(f) To rename the program
File number
[F SET][RENAME]
New file name
[F NAME]
[CAN]
[EXEC]
(3) Related parameters
Channel
I/O=0 I/O=1 I/O=2 I/O=4 (Memory card
interface)
Common Parameter (No. 0100)
Output
format
Parameter
(No. 0101)
Parameter
(No. 0111)
Parameter
(No. 0121)
Specifica-
tion number
Parameter
(No. 0102)
Parameter
(No. 0112)
Parameter
(No. 0122)
Transfer
rate
Parameter
(No. 0103)
Parameter
(No. 0113)
Parameter
(No. 0123)
Transfer
method
Not defined
Connector JD42
0020
I/O channel selection
0: Channel 1
1: Channel 1
2: Channel 2
4: Memory card interface (NC main unit)
6: DNC1/Ethernet (must be set up only if DNC operation is to be
performed)
7: Memory card interface (FANUC touch panel side)
20: Group 0
21: Group 1
35: Group 15
#7
#6 #5 #4 #3 #2 #1 #0
0101
NFD ASI SB2
#7(NFD)0: The feed code is output when data is punched out.
1: The feed code is not output when data is punched out.
#3(ASI) 0: EIA or ISO code is used when data is input.
1: ASCII code is used when data is input.
#0(SB2) 0: The number of stop bits is one.
1: The number of stop bits is two.