Fanuc Power Mate i-D/H Operation Maintenance Handbook

1. SCREEN DISPLAY AND OPERATION
33
1.2.12 Displaying and setting the parameters
See Chapter 8 for details of the parameters.
(1) Press soft key [PARAM].
0000 SEQ INI ISO TVC
0000000
0001 FCV
00000000
0012 MIR
X00000000
Y00000000
Z00000000
0020 I/O CHANNEL 0
0022 0
[][][][][]
DGNOS PMC SYSTEM (OPRT)
PARAMETER (SETTING) O0010 N00002
>_
MDI **** *** *** 15:43:11
PARAM
(2) Entering values from the MDI panel
1 Set PARAMETER WRITE to 1 in the setting screen.
2 Alarm 100 occurs. Press the
CAN
and
RESET
keys simultaneously
to temporarily stop the alarm.
3 Press soft key [(OPRT)] to display the operation menu including
the following:
a) Enter a parameter number and press [NO.SRH]:
Searches for the specified number.
b) Soft key [ON:1]: Sets the value at which the cursor is
positioned to 1. (Only for bit parameters)
c) Soft key [OFF:0]: Sets the value at which the cursor is
positioned to 0. (Only for bit parameters)
d) Soft key [+INPUT]: Adds the entered value to the value at
which the cursor is positioned.
(Only for word parameters)
e) Soft key [INPUT]: Sets the value at which the cursor is
positioned to theentered value.
(Only for word parameters)
f) Soft key [READ]: Inputs parameters from the reader/punch
interface.
g) Soft key [PUNCH]: Outputs parameters to the reader/punch
interface.
(3) Convenient methods for entering data
(a) To change data in units of bits
Pressing
or changes the cursor to 1-bit size, which enables
setting in units of bits (only for bit parameters).