Fanuc Power Mate i-D/H Operation Maintenance Handbook

1. SCREEN DISPLAY AND OPERATION
39
1.2.15 Displaying and setting the pitch error compensation values
(1) Press soft key [PITCH].
PITCH
[][][][][]
SYSTEM (OPRT)
PIT–ERROR SETTING O1234 N00000
NO. DATA
0000 1
0001 0
0002 0
0003 1
0004 –1
0005 0
0006 1
0007 0
0008 0
0009 1
>_
MDI **** *** *** 15:55:24
NO. DATA
0010 0
0011 1
0012 0
0013 –1
0014 2
0015 0
0016 0
0017 1
0018 0
0019 0
NO. DATA
0020 0
0021 1
0022 0
0023 1
0024 3
0025 0
0026 –1
0027 0
0028 0
0029 0
(2) Operation
Compensation number
[NO.SRH]Soft key [(OPRT)]
Compensation value
[+INPUT]
[ON:1]
Compensation value
[INPUT]
[OFF:0]
[READ]
N File number
[EXEC]
[CAN]
Note) EDIT mode
[READ] [EXEC]
[CAN]
Note) EDIT mode