1.2.17 Displaying the operator messages
(1) Press soft key [MSG].
ALARM
[][][][][]
MSGHIS HISTRY
MESSAGE HISTORY
No. 2000
INTERLOCK (*IT1) ON
O1234 N12345
PAGE : 1
(Up to 255
characters)
Display
range
Date, time,
and page
Message
No.
MDI **** *** *** 15:55:24
1.2.18 Displaying the alarm history
(1) Press soft key [HISTRY].
MSGALARM
[][][][][]
HISTRY (OPRT)
ALARM HISTORY O1234 N12345
97/04/18 20:56:26
506 OVERTRAVEL : +X
97/04/18 19:58:11
000 TURN OFF POWER
97/04/18 19:52:45
000 TURN OFF POWER
97/04/18 19:48:43
300 APC ALARM : XAXIS ZERO RETURN REQUEST
97/04/18 18:10:10
507 OVERTRAVEL : +B
MDI **** *** *** 15:55:24
(2) Deleting the alarm history
Press soft key [(OPRT)] and then [CLEAR].
(3) About alarms
D When the parameter (No. 3112#3)=0
1 Alarms generated by a custom macro
The alarms have numbers in the range of 3000 to 3999 and are
referred to as macro alarms in the message.
(Example) #3000=1(ERROR1)
Found as 3001 macro alarm in the history
2 Alarms generated by a DISP or DISPB instruction in the PMC
The alarms have numbers in the range of 1000 to 1999 and are
referred to as external alarms in the message.
(Example) DISP instruction A000.0 1000 ERROR1
Found as 1000 external alarm in the history