1. SCREEN DISPLAY AND OPERATION
43
1.3 Help Function
1 Pressing
HELP
in any screen displays the help screen (except in the
PMC screen).
ALARM
[][][][][]
OPERAT PARAM
HELP (INITIAL MENU) O1234 N00001
*****HELP*****
1. ALARM DETAIL
2. OPERATION METHOD
3. PARAMETER TABLE
S 0 T0000
MEM **** *** *** 00:00:00
1.3.1 Alarm detail screen
1 Pressing soft key [ALARM] while an alarm is generated displays the
help message for the alarm.
ALARM
[][][][][]
OPERAT PARAM (OPRT)
HELP (ALARM DETAIL) O1234 N00001
NUMBER:094
M’SAGE:P TYPE NOT ALLOWED (COORD CHG)
FUNCTION:RESTART PROGRAM
ALARM:
WHEN COORDINATE SYSTEM SETTING IS
CONDUCTED AFTER HOLDING
AUTOMATIC OPERATION, PTYPE (WHEN TOOL
IS DAMAGED) PROGRAM
RESTART CANNOT BE EXECUTED.
S 0 T0000
MEM **** *** *** 00:00:00
2 Press soft key [(OPRT)], enter the alarm number, and then press soft
key [SELECT] to display the help message for the alarm corresponding
to the entered number.