Fanuc Power Mate i-D/H Operation Maintenance Handbook

2. OPERATION LIST
77
Output to external I/O device
Function
KEY
SW
PWE
= 1
Mode
Function
key
Operation
Parameter EDIT [F4] [F8]
PMC
parameter
Impossible
Offset EDIT [F3] [F8]
Custom
macro
variables
EDIT [F3] [F8]
All
programs
EDIT [F2] O to 9999 [F8]
One
program
EDIT [F2] O Program number
[F8]
Input from the personal computer used to operate the DPL/
MDI operation package
Function
KEY
SW
PWE
= 1
Mode
Function
key
Operation
Parameter f EDIT or
emer-
gency
stop
File in the pulldown menu
[Restore] [CNC PA-
RAMETER]
PMC
parameter
EDIT or
emer-
gency
stop
File in the pulldown menu
[Restore] [PMC PA-
RAMETER]
Offset f EDIT or
emer-
gency
stop
File in the pulldown menu
[Restore] [TOOL OFF-
SET]
Custom
macro
variable
f EDIT or
emer-
gency
stop
Read by assigning a tempo-
rary program number,
execute in AUTO mode,
then delete program
Program f EDIT or
emer-
gency
stop
File in the pulldown menu
[Restore] [CNC PRO-
GRAM]
Output to the personal computer used to operate the DPL/
MDI operation package
Function
KEY
SW
PWE
= 1
Mode
Function
key
Operation
Parameter EDIT File in the pulldown menu
[Backup] [CNC PARAME-
TER]
PMC
parameter
EDIT File in the pulldown menu
[Backup] [PMC PA-
RAMETER]
Offset EDIT File in the pulldown menu
[Backup] [TOOL OFF-
SET]

Leave a Reply