Fanuc Power Mate i-D/H Operator Manual

PROGRAMMING
(Common to Power Mate i–D and –H)
B–63174EN/03
13. CUSTOM MACRO
109
Example:
a. To access D0100 to D0103
Set 0 in #1994, then use system variable number #1270 for
access.
b. To access D2000 to D2003
Set 2 in #1994, then use system variable number #1245 for
access.
3. Relationships between variable number 2 and PMC areas that can be
referenced
NOTE
The usable area depends on the PMC type.
(1) Variable timer
Value of #1991 Accessible PMC area
0 T0000 to T0079
1 T0080 to T0159
2 T0160 to T0239
3 T0240 to T0299
(2) Keep replay
Value of #1992 Accessible PMC area
0 K0000 to K0019
1 K0020 to K0039
(3) Counter
Value of #1993 Accessible PMC area
0 C0000 to C0079
1 C0080 to C0159
2 C0160 to C0199
(4) Data table
Value of #1994 Accessible PMC area
0 D0000 to D1859
1 D1000 to D2859
2 D2000 to D3859
3 D3000 to D4859
4 D4000 to D5859
5 D5000 to D6859
6 D6000 to D7859
7 D7000 to D7999
(5) Internal relay
Value of #1995 Accessible PMC area
0 R0000 to R0999
1 R1000 to D1999
2 D2000 to D2999