Fanuc Power Mate i-D/H Operator Manual

3. HIGH–SPEED RESPONSE
FUNCTION
PROGRAMMING
(Power Mate i–H)
B–63174EN/03
246
Number Contents
1063 There is no modal command just after ”N” or ”WHILE”.
Example) GOTO 1 ;
N1 X1000;
There is no modal command in a sub–program
Example) Sub–program O7000
O7000 X100000 ;
M99 ;
A modal command must be given before a motion
command in a sub–program.
O7000 G91 G00
X100000 ;
M99 ;
There is no modal command after sub–program calling command.
Example) Main program O8000
O8000 X100000 ;
M98 P7000 ;
X200000 ;
A modal command must be given between a
sub–program calling command and a motion
command.
O8000 X100000 ;
M98 P7000 ;
G90 G01
X200000 F1000 ;
1064 An attempt was made to specify an out–of–range bit number in
macro variable bit specification. Specify a value within the bit
specification range of 0 to 7.
Example) #1300000.8 = 0 ;
1065 The specified operation command or operator is unusable with bit
specification–type macro variables.
Example) #1300000.0 = #1300000.0 / #1300000.1 ;
1066 An indirect command was issued using a bit specification macro
variable.
1091 The feed rate F is specified in the block including the optional
block skip.
1094 The G code belonging to the G code group 01 is specified in the
block including the optional block skip.
1096 The G code belonging to the G code group 03 is specified in the
block including the optional block skip.
1100 No axis was specified in this program.
1101 No program (O8000 to O8031) to compile is found.
1102 An unusable program number for the motion program is specified
at the function to compile the program by the signal.
1800 One or more motion program are executing.
1821 Compiling operation is done during reset state.
1822 Compiling operation is done during alarm state.
1823 Compiling operation is done during the automatic operation.