3. HIGH–SPEED RESPONSE
FUNCTION
PROGRAMMING
(Power Mate i–H)
B–63174EN/03
262
This function enables to specify the time constant of linear type
acceleration/ deceleration to every block respectively. By this function,
longer time constant can be applied to the block that is required gentle
motion. In other hand, shorter time constant can be applied to other
blocks. Then, as compared with former function, total operation time for
positioning can be shortened.
Shorten
t1
t1t1
t1
t2
In case of former
function
In case of this function
Feedrate
Time
Time
Fig.3.1.10 (a)
3.1.10
G135.3 (Motion
Command with
Acceleration/
deceleration Time
Constant)
Outline