Fanuc Power Mate i-D/H Operator Manual

2. OPERATIONAL DEVICES
B–63174EN/03
OPERATION
342
If a hardware failure or installation error occurs, the system displays one
of the following three types of screens then stops.
Information such as the type of printed circuit board installed in each slot
is indicated. This information and the LED states are useful for failure
recovery.
SLOT CONFIGURATION DISPLAY
0 : 003E4000
1 : 30464202
2 : 00504303
3 :
4 :
5 :
0 :
1 :
2 :
3 :
4 :
5 :
Physical slot number
(secondary)
Information such as the module ID of an installed printed circuit board
Physical slot number
(primary)
Internally–assigned slot number
Module function
Types of printed circuit boards
For more information about the types of printed circuit boards and module
functions, refer to the maintenance manual (B–63175EN).
88E0–01
SLOT 01 (3046) : END
SLOT 02 (3050) :
Blank: Setting not completed
Module ID
Slot number
END: Setting completed
88E0–01
CNC control software
SERVO : 9090–01
OMM: yyyy–yy
PMC: zzzz–zz
Digital servo ROM
Macro exeutor
PMC
The software configuration can be displayed on the system configuration
screen also.
Refer to the MAINTENANCE MANUAL (B–63175EN) for the system
configuration screen.
2.4.2
Screen Displayed at
Power–on
Slot status display
Screen indicating
module setting status
Display of software
configuration