Fanuc Power Mate i-D/H Operator Manual

3. MANUAL OPERATION
B–63174EN/03
OPERATION
348
Feedrate, time constant and method of automatic acceleration/
deceleration for manual rapid traverse are the same as G00 in programmed
command.
Changing the mode to the jog mode while pressing a feed axis and
direction selection switch does not enable jog feed. To enable jog feed,
enter the jog mode first, then press a feed axis and direction selection
switch.
If reference position return is not performed after power–on, pushing
RAPID TRAVERSE button does not actuate the rapid traverse but the
remains at the JOG feedrate. This function can be disabled by setting bit
1 (RPD) of parameter No.1401.
NOTE
When bit 6 (NJH) of parameter No. 7104 is set to 0, the
manual pulse generator is enabled in the jog feed mode.
Set bit 6 (NJH) of parameter No. 7104 to 1 to disable the
manual pulse generator in the jog feed mode.
Restrictions
Acceleration/
deceleration for rapid
traverse
Change of modes
Rapid traverse prior to
reference position return