Fanuc Power Mate i-D/H Operator Manual

3. MANUAL OPERATION
B–63174EN/03
OPERATION
354
Coordinates when the feed hold button is pressed while block (2) is being
executed, manual operation (Y–axis +75.0) is performed, the control unit
is reset with the RESET button, and block (2) is read again
(300.0 , 275.0)
(200.0,150.0)
(300.0 , 200.0)
(150.0 , 200.0)
(200.0,225.0)
(150.0 , 125.0)(100.0 , 100.0)
Y
X
Switch OFF
Switch ON
Manual
operation
When there is only one axis in the following command, only the
commanded axis returns.
Manual
operation
N2
N1
N3
N1G01X100.0Y100.0F500;
N2X200.0;
N3Y150.0;
Y
X
(100.0 , 100.0)
(200.0 , 100.0)
(200.0 , 150.0)
Switch OFF
Switch ON
When the following commands are incremental commands, operation is
the same as when the switch is OFF.
When reset after a
manual operation
following a feed hold
When a movement
command in the next
block is only one axis
When the next move
block is an incremental

Leave a Reply