Fanuc Power Mate i-D/H Operator Manual

4. AUTOMATIC OPERATION
B–63174EN/03
OPERATION
356
Programs are registered in memory in advance. When one of these
programs is selected and the cycle start switch on the machine operators
panel is pressed, automatic operation starts, and the cycle start LED goes
on.
When the feed hold switch on the machine operators panel is pressed
during automatic operation, automatic operation is stopped temporarily.
When the cycle start switch is pressed again, automatic operation is
restarted.
When the reset switch on the CRT/MDI panel is pressed, automatic
operation terminates and the reset state is entered.
The following procedure is given as an example. For actual operation,
refer to the manual supplied by the machine tool builder.
Procedure for AUTO Operation
1 Press the AUTO mode selection switch.
2 Select a program from the registered programs. To do this, follow the
steps below.
2–1 Press
PROG
to display the program screen.
2–2 Press address
O
.
2–3 Enter a program number using the numeric keys.
2–4 Press the [O SRH] soft key. (CRT/MDI)
Press the
key. (DPL/MDI)
3 Press the cycle start switch on the machine operators panel.
Automatic operation starts, and the cycle start LED goes on. When
automatic operation terminates, the cycle start LED goes off.
4 To stop or cancel AUTO operation midway through, follow the steps
below.
a. Stopping AUTO operation
Press the feed hold switch on the machine operators panel. The
feed hold LED goes on and the cycle start LED goes off. The
machine responds as follows:
(i) When the machine was moving, feed operation decelerates
and stops.
(ii) When dwell was being performed, dwell is stopped.
(iii) When M, S, or T was being executed, the operation is
stopped after M, S, or T is finished. When the cycle start
switch on the machine operators panel is pressed while the
feed hold LED is on, machine operation restarts.
b.
Terminating AUTO operation
Press the
RESET
key on the CRT/MDI panel.
Automatic operation is terminated and the reset state is entered.
When a reset is applied during movement, movement
decelerates then stops.
4.1
AUTO OPERATION
Procedure