Fanuc Power Mate i-D/H Operator Manual

B–63174EN/03
5. TEST OPERATION
OPERATION
373
The tool is moved at the feedrate specified by a parameter regardless of
the feedrate specified in the program. This function is used for checking
the movement of the tool.
Tool
Table
Fig.5.4 Dry run
Procedure for Dry Run
Press the dry run switch on the machine operators panel during automatic
operation.
The tool moves at the feedrate specified in a parameter. The rapid traverse
switch can also be used for changing the feedrate.
Refer to the appropriate manual provided by the machine tool builder for
dry run.
The dry run feedrate changes as shown in the table below according to the
rapid traverse switch and parameters.
Rapid traverse
Program command
Rapid
traverse
button
Rapid traverse Feed
ON Rapid traverse rate Dry run feedrateMax.JV(*2)
OFF Dry run speedJV,or rapid
traverse rate (*1)
Dry run feedrateJV(*2)
Max. feedrate of command Setting by parameter No.1422. . . . . . . . . .
Rapid traverse rate Setting by parameter No.1420. . . . . . . . . . . . . . . . .
Dry run feedrate Setting by parameter No.1410. . . . . . . . . . . . . . . . . . .
(*1):Dry run feedrate x JV when bit 6 (RDR) of parameter No.1401 is 1.
Rapid traverse rate when parameter RDR is 0.
JV : Jog feedrate override
(*2):Clamped to a maximum cutting feedrate.
JVmax : Maximum jog feedrate override value
5.4
DRY RUN
Procedure
Explanation
Dry run feedrate
DRY
RUN
MC
LOCK
SINGLE
BLOCK
OPT
STOP
MST
LOCK
BLOCK
SKIP
WORK
LIGHT

Leave a Reply