Fanuc Power Mate i-D/H Operator Manual

B–63174EN/03
5. TEST OPERATION
OPERATION
375
If G28 to G30 are issued, the single block function is effective at the
intermediate point.
In a canned cycle, the single block stop points are the end of , , and
shown below. When the single block stop is made after the point
or , the feed hold LED lights.
Rapid traverse
Feed
Fig.5.5 (b) Single block during canned cycle
Single block stop is not performed in a block containing M98P_;. M99;
or G65.
However, single block stop is even performed in a block with M98P_ or
M99 command, if the block contains an address other than O, N or P.
Explanation
Reference position
return and single block
Single block during a
canned cycle
(For the Power Mate
i–D/D2)
Subprogram call and
single block