Fanuc Power Mate i-D/H Operator Manual

7. ALARM AND SELF–DIAGNOSIS
FUNCTIONS
B–63174EN/03
OPERATION
383
Up to 50 of the most recent CNC alarms are stored and displayed on the
screen.
Display the alarm history as follows:
Procedure for Alarm History Display
1 Press the function key
MESSAGE
.
2 Press the chapter selection soft key
[HISTRY].
The alarm history appears.
The following information items are displayed.
(1) The data the alarm was issued
(2) Alarm No.
(3) Alarm message (some contains no message)
3 Change the page by the 1–page change key.
4 To delete the recorded information, press the softkey
[(OPRT)] then
the [DELETE] key.
ALARM HISTORY O0100 N00001
AUTO
* * * *
* * * * * *
19:47:45
(1)02/02/14 16:43:48
(2)010 (3)MPROPER G–CODE
02/02/13 8:22:21
506 OVER TRAVEL : +X
02/02/12 20:15:43
417 SERVO ALARM : X AXIS DGTL PARAM
PAGE=1
(4)
[][][][][]ALARM MSG HISTRY (OPRT)
(1) The data the alarm was issued
(2) Alarm No.
(3) Alarm message (some contains no message)
(4) Page No.