Fanuc Power Mate i-D/H Operator Manual

7. ALARM AND SELF–DIAGNOSIS
FUNCTIONS
B–63174EN/03
OPERATION
388
1 byte of flag bits 1–byte decimal 2–byte decimal 4–byte decimal
NOTE
The size for the data format currently selected corresponds
to the difference between a displayed number and a number
displayed below it.
Ending PMC data display
Pressing
No.
, numeral, and
INPUT
redisplays the diagnosis screen.
Setting PMC data
PMC data can be set from the DPL/MDI when setting parameter
DWE is set to 1.
1 Select the setting parameter display.
2 Use the cursor keys to position the cursor on DWE.
Press
1
and
INPUT
to set DWE to 1.
WARNING
When not setting PMC data, set DWE to 0 so that PMC data
is not set inadvertently.
3 Select a PMC address and enter a number.
> D0100 00000000
D0101 00001010
Example: Enter 100 in decimal in the address data of D0100.
4 Press the
.
key to select a data format.
> D0100 0
D0101 10
5 Use the numeric keys to enter a value.
> D0100 0
D0100= 100_
Procedure
Procedure