Fanuc Power Mate i-D/H Operator Manual

8. DATA INPUT/OUTPUT
B–63174EN/03
OPERATION
404
Parameters and pitch error compensation data are entered using different
screens. This chapter describes operations required.
Parameters are loaded into the memory of the controller unit from a floppy
or NC tape. The input format is the same as the output format. See
V–
8.6.2. When a parameter is loaded which has the same data number as
a parameter already registered in the memory, the loaded parameter
replaces the existing parameter.
Inputting parameters
1 Make sure the input device is ready for reading.
When using the Power Mate i–D2, select a path for which parameters
are to be entered, with the path selection switch or MDI keyboard.
2 When using a floppy, search for the required file according to the
procedure in V–
8.2.
3 Press the EMERGENCY STOP button on the machine operators panel.
4 Press function key
OFFSET
SETTING
.
5 Press the soft key [SETING]
for chapter selection.
6 Enter 1 in response to the prompt for writing parameters (PWE).
Alarm P/S100 (indicating that parameters can be written) appears.
7 Press soft key
SYSTEM
.
8 Press chapter selection soft key [PARAM], Then the parameter
screen appears.
9 Press soft key [(OPRT)].
10 Press the rightmost soft key
(next–menu key).
11 Press soft keys [READ] and [EXEC].
Parameters are read into memory. Upon completion of input, the
“INPUT” indicator at the lower–right corner of the screen disappears.
12 Press function key
OFFSET
SETTING
.
13 Press soft key [SETING] for chapter selection.
14 Enter 0 in response to the prompt for writing the setting data
parameters.
15 Turn the power to the CNC back on.
16 Release the EMERGENCY STOP button on the machine operators
panel.
8.6
INPUTTING AND
OUTPUTTING
PARAMETERS AND
PITCH ERROR
COMPENSATION
DATA
8.6.1
Inputting Parameters
Procedure (CRT/MDI)

Leave a Reply