Fanuc Power Mate i-D/H Operator Manual

8. DATA INPUT/OUTPUT
B–63174EN/03
OPERATION
410
All pitch error compensation data are output in the defined format from
the memory of the CNC to a floppy or NC tape.
Outputting Pitch Error Compensation Data
1 Make sure the output device is ready for output.
When using the Power Mate i–D2, select a path whose pitch error
compensation data is to be output, with the path selection switch or
MDI keyboard.
2 Specify the punch code system (ISO or EIA) using a parameter.
3 Press the EDIT switch on the machine operators panel.
4 Press function key
SYSTEM
.
5 Press the rightmost soft key
(next–menu key) and press chapter
selection soft key [PITCH].
6 Press soft key
[(OPRT)].
7 Press rightmost soft key
(next–menu key).
8 Press soft keys [PUNCH] and [EXEC].
All parameters are output in the defined format.
1 Select the EDIT mode.
2 Execute file heading when required.
3 Select the Pitch error compensation data display screen by
DGNOS/
PARAM
key.
4 Press the
WRITE
key.
Output format is as follows:
N 10000 P ;. . . . . . . .
N 11023 P ;. . . . . . . .
N: Pitch error compensation point No. +10000
P : Pitch error compensation data
When the floppy disk directory display function is used, the name of the
output file is [PITCH ERROR].
8.6.4
Outputting Pitch Error
Compensation Data
Procedure (CRT/MDI)
Procedure (DPL/MDI)
Explanations
Output format
Output file name