Fanuc Power Mate i-D/H Operator Manual

8. DATA INPUT/OUTPUT
B–63174EN/03
OPERATION
428
Parameters can be input and output using the ALL IO screen.
Inputting parameters
1 Press soft key [PARAM] on the ALL IO screen, described in Section
8.9.1.
2 Select EDIT mode.
3 Press soft key [(OPRT)]. The screen and soft keys change as shown
below.
READ/PUNCH (PARAMETER) O1234 N12345
MDI
*
* * * * * * * * * * * *
12:34:56
I/O CHANNEL 0 TV CHECK OFF
DEVICE NUM. 3 PUNCH CODE ISO
BAUDRATE 9600 INPUT CODE EIA/ISO
STOP BIT 2 FEED OUTPUT FEED
NULL INPUT (EIA) NO EOB OUTPUT (ISO) CR
TV CHECK (NOTES) ON
(0:EIA 1:ISO)>1_
[][][][][]
READ PUNCH
4 Press soft key [READ], then [EXEC].
The parameters are read, and the “INPUT” indicator blinks at the
lower–right corner of the screen. Upon the completion of input, the
“INPUT” indicator is cleared from the screen.
To cancel input, press soft key [CAN].
8.9.3
Inputting and
Outputting Parameters
Procedure
EXECCAN