Fanuc Power Mate i-D/H Operator Manual

PROGRAMMING
(Common to Power Mate i–D and –H)
B–63174EN/03
3. PREPARATORY FUNCTION
(G FUNCTION)
33
G code FunctionGroup
G90
03
Absolute command
G91
03
Increment command
G92 00
Setting for workpiece coordinate system or clamp at maximum spindle
speed
G93 Rate function
G94 05 Feed per revolution
G95 Feed per minute
G96
13
Constant surface speed control
G97
13
Constant surface speed control cancel
G130
00
Multi path control
G135.1
00
High–speed response function continuous feed
G140 00 Phase matching with the electronic cam function
G145 05 Mechanical synchronization
G146 05 Start point synchronization
NOTE
The G codes of groups 09 and 13, and G92 for clamping at a maximum spindle speed are valid
only with the Power Mate i–D/D2.
G05, G130, G135.1, G140, G145, and G146 are valid only with the Power Mate i–H.