Fanuc Power Mate i-D/H Operator Manual

B–63174EN/03
11. SETTING AND DISPLAYING DATA
OPERATION
513
Displays the current position of the tool in the workpiece coordinate
system. The current position changes as the tool moves. The least input
increment is used as the unit for numeric values. The title at the top of
the screen indicates that work coordinates are used.
Display the current position screen in the workpiece coordinate system
1 Press function key
POS
.
2 Press soft key
[WORK].
AUTO STRT MTN *** 09:06:35
ACTUAL POSITION(WORK) O1000 N00010
PART COUNT 5
RUN TIME 0H15M CYCLE TIME 0H 0M38S
ACT.F 3000 MM/M
S 0 T0000
X 123.456
Y 363.233
[][][][][]WORK REL ALL HNDL (OPRT)
AUTO **** *** *** 19:33:33 PATH 1
ACTUAL POSITION(ABSOLUTE) O1000 N00000
PART COUNT 15
RUN TIME 0H13M CYCLE TIME 0H 0M 0S
ACT.F 0 MM/M
X
1
0.000
[][][][][]ABS REL ALL HNDL (OPRT)
Power Mate i–D
Display in two–path control
11.1.1
Position Display in the
Workpiece Coordinate
System
Procedure for CRT/MDI