Fanuc Power Mate i-D/H Operator Manual

11. SETTING AND DISPLAYING DATA
B–63174EN/03
OPERATION
520
The actual feedrate on the machine (per minute) can be displayed on a
current position display screen or program check screen by setting bit 0
(DPF) of parameter No. 3105.
Display for the actual feedrate on the current position display screen
1 Press function key
POS
to display a current position display screen.
AUTO STRT MTN *** 09:06:35
ACTUAL POSITION(WORK) O1000 N00010
PART COUNT 5
RUN TIME 0H15M CYCLE TIME 0H 0M38S
ACT.F 3000 MM/M
S 0 T0000
X 123.456
Y 363.233
[][][][][]WORK REL ALL HNDL (OPRT)
Actual feedrate is displayed after ACT.F.
The actual feedrate is displayed in units of millimeter/min or inch/min
(depending on the specified least input increment) under the display of the
current position.
The actual rate is calculated by the following expression:
Fact
n
i1
(fi)
2
where
n : Number of axes
fi : Cutting feed rate in the tangential direction of each axis or rapid
traverse rate
Fact : Actual feedrate displayed
The display unit: mm/min (metric input).
inch/min (Inch input, Two digits below the decimal
point are displayed.)
The feedrate along the PMC axis can be omitted by setting bit 1 (PCF) of
parameter No. 3105.
In the case of feed per revolution, the actual feedrate displayed is the feed
per minute rather than feed per revolution.
In the case of movement of rotary axis, the speed should be displayed in
units of deg/min but is displayed on the screen in units of input system
at that time. For example, when the rotary axis moves at 50 deg/min with
inch system machine, the following is displayed: 0.50 INCH/M
The program check screen also displays the actual feedrate.
11.1.4
Actual Feedrate
Display
Procedure for CRT/MDI
Explanations
Actual feedrate value
Actual feedrate display
of feed per revolution
Actual feedrate display
of rotary axis
Actual feedrate display
on the other screen