Fanuc Power Mate i-D/H Operator Manual

B–63174EN/03
11. SETTING AND DISPLAYING DATA
OPERATION
535
Data such as the TV check flag and punch code is set on the setting data
screen. On this screen, the operator can also enable/disable parameter
writing, and enable/disable the automatic insertion of sequence numbers
in program editing.
See V–10.2 for automatic insertion of sequence numbers.
This subsection describes how to set data.
Setting the Setting Data
1 Select the MDI mode.
2 Press function key
OFFSET
SETTING
.
3 Press soft key
[SETING] to display the setting data screen.
This screen consists of several pages.
Press page key
PAGE
or
PAGE
until the desired screen is displayed.
An example of the setting data screen is shown below.
SETTING (HANDY) O0001 N00000
> _
MDI **** *** *** 16:05:59
PARAMETER WRITE = 1 (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 1 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–2:CHANNEL NO.)
SEQUENCE NO. = 0 (0:OFF 1:ON)
[][][][][]OFFSET SETING (OPRT)
SETTING (HANDY) O0001 N00000
> _
MDI **** *** *** 16:05:59
MIRROR IMAGE X = 0 (0:OFF 1:ON)
MIRROR IMAGE Y = 0 (0:OFF 1:ON)
[][][][][]OFFSET SETING (OPRT)
11.4.3
Displaying and
Entering Setting Data
Procedure for CRT/MDI

Leave a Reply