Fanuc Power Mate i-D/H Operator Manual

11. SETTING AND DISPLAYING DATA
B–63174EN/03
OPERATION
550
Enabling/displaying Parameter Writing
1 Select the MDI mode or enter state emergency stop.
2 Press function key
OFFSET
SETTING
.
3 Press soft key [SETING] to display the setting screen.
SETTING (HANDY) O0001 N00000
> _ S 0 T0000
MDI **** *** *** 16:05:59
PARAMETER WRITE = 1 (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 1 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–2:CHANNEL NO.)
SEQUENCE NO. = 0 (0:OFF 1:ON)
[][][][][]OFFSET SETING (OPRT)
4 Move the cursor to PARAMETER WRITE using cursor keys.
5 Press soft key [(OPRT)], then press [1: ON] to enable parameter
writing.
At this time, the CNC enters the P/S alarm state (No.100).
6 After setting parameters, return to the setting screen. Move the cursor
to PARAMETER WRITE and press soft key [(OPRT)] , then press
[0: OFF].
7 Depress the
RESET
key to release the alarm condition. If alarm No.000
has occurred, however, turn off the power supply and then turn it on,
otherwise the alarm is not released.
1 Press the
VAR
key to display the settings screen.
2 Use the cursor keys to position the cursor at PWE.
3 Press the
1
key and the
INPUT
key, in that order, to enable
parameters to be written. The CNC unit will generate P/S alarm 100.
4 Press the
DGNOS/
PARAM key to display the parameter screen.
> &0001 01010101
&0002 01010101
Procedure for CRT/MDI
Procedure for DPL/MDI

Leave a Reply