Fanuc Power Mate i-D/H Operator Manual

B–63174EN/03
11. SETTING AND DISPLAYING DATA
OPERATION
553
Displaying and Setting the Pitch Error Compensation Data
1 Set the following parameters:
Number of the pitch error compensation point at the reference
position (for each axis): Parameter 3620
Number of the pitch error compensation point having the smallest
value (for each axis): Parameter 3621
Number of the pitch error compensation point having the largest
value (for each axis): Parameter 3622
Pitch error compensation magnification (for each axis): Parameter
3623
Interval of the pitch error compensation points (for each axis):
Parameter 3624
2 Press function key
SYSTEM
.
3 Press the continuous menu key
, then press chapter selection soft
key
[PITCH].
The following screen is displayed:
PIT–ERROR SETTING O0000 N00000
NO. DATA
0000 0
0001 0
0002 0
0003 0
0004 0
0005 0
0006 0
0007 0
0008 0
0009 0
NO. DATA
0010 0
0011 0
0012 0
0013 0
0014 0
0015 0
0016 0
0017 0
0018 0
0019 0
NO. DATA
0020 0
0021 0
0022 0
0023 0
0024 0
0025 0
0026 0
0027 0
0028 0
0029 0
(X)
> _
AUTO **** *** *** 16:05:59
[][][][][]
NO.SRH ON:1 OFF:0 +INPUT –INPUT
4 Move the cursor to the compensation point number to be set in either
of the following ways:
Enter the compensation point number and press the [NO.SRH]
soft
key.
Move the cursor to the compensation point number using the page
keys,
PAGE
and
PAGE
, and cursor keys, , , , and .
5 Enter a value with numeric keys and press the [INPUT] soft key.