Fanuc Power Mate i-D/H Operator Manual

12. DISPLAY UNIT SHARING FUNCTION
B–63174EN/03
OPERATION
560
NOTE
1 Device number for each Power Mate is set by using the 7–segment LED and the push switch
on the front face of the control unit. For the details, refer to the maintenance manual of FANUC
Power Mate i–MODEL D/H(B–63175EN)
2 The shared screen can not be displayed on the LCD/MDI with touch panel.
3 To identify each Power Mate, a name can be given by the parameter No.3141–No.3146. This
name is displayed on the left side of shared screen. And ”AL” is displayed under the device
name when alarm occurs.
4 When one display unit is shared by plural Power Mate units, set the total number of connected
Power Mates units to the parameter No.3170.This parameter should be set only to the Power
Mate #0. When Power Mate unit with three or more controlled axes exists, add 128 to the total
number of Power Mate units.