Fanuc Power Mate i-D/H Operator Manual

B–63174EN/03
1. DAILY MAINTENANCE
MAINTENANCE
571
(1) Absolute pulsecoder battery
When using the absolute pulsecoder, replace the battery quickly when
one of the alarms 306-308 is displayed on CRT/MDI.
A battery is built into the α series servo amplifier or β series servo
amplifier.
Carry out the battery replacement in the “Power ON” state.
Be careful with the battery polarity: do not insert the wrong way
around.
Use only the specified replacement battery (lithium battery :
A06B–6073–K001). Battery life is approximately one year;
therefore replace regularly once a year even if the above alarm does
not occur.
Fig.1.2 Mounting location of lithium battery in α series servo amplifier
1.2
BATTERY
REPLACEMENT