Fanuc Power Mate i-D/H Operator Manual

B. LIST OF FUNCTIONS AND
TAPE FORMAT
B–63174EN/03
APPENDIX
581
Functions Tape formatIllustration
Electronic cam operation with the elec-
tronic cam function (G05)
Cam
shaft phase
Cam 1
displacement
Cam 2
displacement
Cam 3
displacement
G05 P23001 L_ ;
L_: Specify the number of executions
(1 to 99999999). One rotation of
the cam shaft in the forward
direction from the electronic cam
operation start position is
counted as +1, and one rotation
of the cam shaft in the reverse
direction is counted as –1. When
a L count is reached, the
operation stops. When 0 is
specified, a continuous operation
is performed.
Advanced preview feed forward (G08)
G08 P1 ; Advanced preview feed
forward mode on
G08 P0 ; Advanced preview feed
forward mode off
Exact stop (G09)
Time
Speed
In–position check
G01
P_ ;
G02
G03
G09
Change of offset value by program
(G10)
G10 L11 P_R_;

Leave a Reply