Fanuc Power Mate i-D/H Operator Manual

C. RANGE OF COMMAND VALUE
B–63174EN/03
APPENDIX
586
C
RANGE OF COMMAND VALUE
Increment system
IS–A IS–B IS–C
Least input increment 0.01 mm 0.001 mm 0.0001 mm
Least command increment 0.01 mm 0.001 mm 0.0001 mm
Max. programmable dimension ±999999.99 mm ±99999.999 mm ±9999.9999 mm
Max. rapid traverse NOTE1 240000 mm/min 240000 mm/min 100000 mm/min
Feedrate range NOTE1 1 to 240000
mm/min
1 to 240000 mm/
min
1 to 100000 mm/
min
Incremental feed 0.01, 0.1, 1,
10 mm/step
0.001, 0.01, 0.1,
1 mm/step
0.0001, 0.001,
0.01, 0.1 mm/
step
Tool compensation 0 to ±9999.99
mm
0 to ±999.999
mm
0 to ±999.9999
mm
Dwell time 0 to 999999.99
sec
0 to 99999.999
sec
0 to 9999.9999
sec
Increment system
IS–A IS–B IS–C
Least input increment 0.001 inch 0.0001 inch 0.00001 inch
Least command increment 0.01 mm 0.001 mm 0.0001 mm
Max. programmable dimension ±99999.999 inch ±9999.9999 inch ±393.70078 inch
Max. rapid traverse NOTE1 240000 mm/min 240000 mm/min 100000 mm/min
Feedrate range NOTE1 0.01 to 9600
inch/min
0.01 to 9600
inch/min
0.01 to 4000
inch/min
Incremental feed 0.001, 0.01, 0.1,
1 inch/step
0.0001, 0.001,
0.01, 0.1 inch/
step
0.00001, 0.0001,
0.001, 0.01 inch/
step
Tool compensation 0 to ±999.999
inch
0 to ±99.9999
inch
0 to ±99.99999
inch
Dwell time 0 to 999999.99
sec
0 to 99999.999
sec
0 to 9999.9999
sec
Linear axis
In case of millimeter
input, feed screw is
millimeter
In case of inch input,
feed screw is millimeter