Fanuc Power Mate i-D/H Operator Manual

E. STATUS WHEN TURNING POWER ON,
WHEN CLEAR AND WHEN RESET
B–63174EN/03
APPENDIX
593
E
STATUS WHEN TURNING POWER ON, WHEN CLEAR
AND WHEN RESET
Bit 6 (CLR) of parameter No.3402 is used to select whether resetting the
CNC places it in the cleared state or in the reset state (0: reset state/1:
cleared state).
The symbols in the tables below mean the following :
: The status is not changed or the movement is continued.
: The status is cancelled or the movement is interrupted.
Item When turning power on Cleared Reset
Setting
data
Offset value
d
a
t
a
Data set by the MDI
setting operation
Parameter
Various
data
Programs in memory
d
a
t
a
Contents in the buffer
storage
: MDI mode
: Other mode
Display of sequence
number
(Note 1) (Note 1)
One shot G code
Modal G code Initial G codes.
(The G20 and G21 codes re-
turn to the same state they
were in when the power was
last turned off.)
Initial G codes.
(G20/G21 are not
changed.)
F Zero Zero
S, T, M (Note3)
Work coordinate value Zero
Action in
opera
-
Movement
opera-
tion
Dwell
Issuance of M, S and
T codes (Note3)
Tool length com-
pensation
Depending on bit 6 (LVK)
of parameter No.5003
: MDI mode
Other modes
depend on
bit 6 (LVK) of
parameter No.5003.
Storing called subpro-
gram number
(Note 2) : MDI mode
: Other modes (Note
2)

Leave a Reply