Fanuc Power Mate i-D/H Operator Manual

E. STATUS WHEN TURNING POWER ON,
WHEN CLEAR AND WHEN RESET
B–63174EN/03
APPENDIX
594
Item ResetClearedWhen turning power on
Output
signals
CNC alarm signal AL Extinguish if there is no cause
for the alarm
Extinguish if there is no
cause for the alarm
Extinguish if there is no
cause for the alarm
Reference position
return completion ZPn
( : Emergency stop) ( : Emergency stop)
S and T codes
(Note3)
M code
M, S and T strobe sig-
nals (Note3)
Spindle revolution sig-
nal (S analog signal)
(Note3)
CNC ready signal MA ON
Servo ready signal
SA
ON (When other than
servo alarm)
ON (When other than
servo alarm)
ON (When other than
servo alarm)
Cycle start LED (STL)
Feed hold LED (SPL)
NOTE
1 When heading is performed, the main program number is displayed.
2 When a reset is performed during execution of a subprogram, control returns the main program
by heading function.
Execution cannot be started from the middle of the subprogram.
3 S function, spindle revolution signal and K data of canned cycle are available for the Power
Mate i–D/D2 only.