Fanuc Power Mate i-D/H Operator Manual

G. ALARM LIST
B–63174EN/03
APPENDIX
600
Number ContentsMessage
205 RIGID MODE DI SIGNAL OFF Rigid tapping signal (DGNG 061#1) is not 1 when G84 (G74) is
executed though the rigid M code (M29) is specified.Consult the PMC
ladder diagram to find the reason the DI signal is not turned on.
Modify the program.
206 CAN NOT CHANGE PLANE (RIGID
TAP)
Plane changeover was instructed in the rigid mode.
Correct the program.
207 RIGID DATA MISMATCH The specified distance was too short or too long in rigid tapping.
213 ILLEGAL COMMAND IN
SYNCHRO–MODE
Any of the following alarms occurred in the operation with the simple
synchronization control.
1) The program issued the move command to the slave axis.
2) The program issued the manual continuous feed/manual handle
feed/incremental feed command to the slave axis.
3) The program issued the automatic reference position return
command without executing the manual reference position return
after the power was turned on.
4) The difference between the position error amount of the master and
slave axes exceeded the value specified in parameter No. 8313.
214 ILLEGAL COMMAND IN
SYNCHRO–MODE
Coordinate system is set or tool compensation of the shift type is
executed in the synchronous control. Correct the program.
224 RETURN TO REFERENCE POINT Reference position return has not been performed before the auto-
matic operation starts. Perform reference position return only when
bit 0 of parameter 1005 ZRN
X
is 0.
231 ILLEGAL FORMAT IN G10 OR L50 Any of the following errors occurred in the specified format at the pro-
grammable–parameter input.
1) Address N or R was not entered.
2) A number not specified for a parameter was entered.
3) The axis number was too large.
4) An axis number was not specified in the axis–type parameter.
5) An axis number was specified in the parameter which is not an axis
type.
233 DEVICE BUSY When an attempt was made to use a unit such as that connected via
the RS–232–C interface, other users were using it.
239 BP/S ALARM While punching was being performed with the function for controlling
external I/O units ,background editing was performed.
240 BP/S ALARM Background editing was performed during MDI operation.
5010 END OF RECORD The end of record (%) was specified.
5134 FSSB : OPEN READY TIME OUT Initialization did not place FSSB in the open ready state.
5135 FSSB : ERROR MODE FSSB has entered error mode.
5136 FSSB : NUMBER OF AMPS IS
SMALL
In comparison with the number of controlled axes, the number of am-
plifiers recognized by FSSB is not enough. This occurs also if there is
a poor connection in the FSSB optical cable when the power is
switched on.
5137 FSSB : CONFIGURATION ERROR FSSB detected a configuration error.
5138 FSSB : AXIS SETTING NOT
COMPLETE
In automatic setting mode, axis setting has not been made yet.
Perform axis setting on the FSSB setting screen.
5139 FSSB : ERROR Servo initialization did not terminate normally.
The optical cable may be defective, or there may be an error in connec-
tion to the amplifier or another module.
Check the optical cable and the connection status.
5197 FSSB : OPEN TIME OUT The CNC permitted FSSB to open, but FSSB was not opened.
5198 FSSB : ID DATA NOT READ Temporary assignment failed, so amplifier initial ID information could
not be read.