Fanuc Power Mate i-D/H Operator Manual

B–63174EN/03
G. ALARM LIST
APPENDIX
609
10) Over travel alarms
Number Message Contents
500 OVER TRAVEL : +n Exceeded the n–th axis + side stored stroke limit.
(Parameter No.1320)
501 OVER TRAVEL : –n Exceeded the n–th axis – side stored stroke limit.
(Parameter No.1321)
506 OVER TRAVEL : +n Exceeded the n–th axis + side hardware OT.
507 OVER TRAVEL : –n Exceeded the n–th axis – side hardware OT.
11) Overheat alarms
Number Message Contents
700 OVERHEAT: CONTROL UNIT Control unit overheat
Check that the fan motor in the control unit operates normally, and
clean the air filter in the cabinet.
701 OVERHEAT: FAN MOTOR The fan motor on the top of the cabinet for the contorl unit is over-
heated. Check the operation of the fan motor and replace the motor if
necessary. This alarm occurs also if the fan unit has not been con-
nected.
12) Rigid tapping alarm
Number Message Contents
740 RIGID TAP ALARM : EXCESS
ERROR
During rigid tapping, the position deviation of the spindle in the stop
state exceeded the setting.
741 RIGID TAP ALARM : EXCESS
ERROR
During rigid tapping, the position deviation of the spindle in the stop
state exceeded the setting.
742 RIGID TAP ALARM : LSI OVER
FLOW
During rigid tapping, an LSI overflow occurred on the spindle side.
13) Spindle alarms
Number Message Contents
749 S–SPINDLE LSI ERROR A communication error occurred for the serial spindle. The cause
may be the disconnection of an cable or the interruption of the power
to the spindle amplifier.
(Note) Unlike spindle alarm No. 750, this alarm occurs when a serial
communication alarm is detected after the spindle amplifier is
normally activated.
750 SPINDLE SERIAL LINK START
FAULT
This alarm is generated when the spindle control unit is not ready for
starting correctly when the power is turned on in the system with the
serial spindle.
The four reasons can be considered as follows:
1) Defective cable, poor connection, or spindle amplifier being
switched off
2) When the NC power was turned on under alarm conditions other
than SU–01 or AL–24 which are shown on the LED display of the
spindle control unit.
In this case, turn the spindle amplifier power off once and perform
startup again.
3) Other reasons (improper combination of hardware)
This alarm does not occur after the system including the spindle
control unit is activated.
See diagnostic display No. 409 for details.

Leave a Reply