Fanuc Power Mate i-D/H Operator Manual

PROGRAMMING
(Common to Power Mate i–D and –H)
B–63174EN/03
6. REFERENCE POSITION
65
NOTE
1 To this feedrate, a rapid traverse override (F
0
,25,50,100%)
is applied, for which the setting is 100%.
2 After a machine coordinate system has been established
upon the completion of reference position return, the
automatic reference position return feedrate will conform to
the ordinary rapid traverse rate.
3 For the manual rapid traverse rate used before a machine
coordinate system is established upon the completion of
reference position return a jog feedrate or manual rapid
traverse rate can be selected using bit 0 (RPD) of parameter
No.1401.
Before a coordinate
system is established
After a coordinate
system is established
Automatic reference posi-
tion return (G28)
No.1428 No.1420
Automatic rapid traverse
(G00)
No.1428 No.1420
Manual reference position
return
No.1428 No.1428
Manual rapid traverse rate No.1423 *1 No.1424
NOTE
When parameter No.1428 is set to 0, the feedrates conform
to the parameter settings shown below.
Before a coordinate
system is established
After a coordinate
system is established
Automatic reference posi-
tion return (G28)
No.1420 No.1420
Automatic rapid traverse
(G00)
No.1420 No.1420
Manual reference position
return
No.1424 No.1424
Manual rapid traverse rate No.1423 *1 No.1424
1420 : Rapid traverse rate
1423 : Jog feedrate
1424 : Manual rapid traverse rate
*1 Setting of parameter No.1424 when bit 0 (RPD) of parameter No.1401
is set to 1.

Leave a Reply

Your email address will not be published. Required fields are marked *