FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
B63173EN/03
148
Ambient temperature During operation 0° to 58°C
During storage and transportation 20°C to 60°C
Relative humidity 30 to 95% (no condensation)
Vibration During operation: 0.5 G or less
Environment Inter of units: Each unit should be placed in a cabinet
to keep it from pollutants (such as dust, coolant,
organic solvents, acid, corrosive gas, and salt).
Other requirements (1) Install the I/O module in a fully enclosed cabinet.
Item Specification Remarks
Operators panel I/O
module AI
A20B20020470 Generalpurpose DI: 16 points
Matrix DI: 56 points
DO: 56 points
MPG interface is supported.
Fuse (replacement part) A03B0815K001 1A
Item Specification Remarks
Generalpurpose DI 16 points 24V input
Matrix DI 56 points (8 × 7) 5V input
DO points 56 points 24 V source type output
Power Mate interface FANUC I/O Link
connection
Up to 16 modules can be
connected as Power Mate
slaves. Or, a maximum of 1024
points can be supported on
both the input and output sides.
MPG interface Max. 3 units
6.8.9
Specifications
Installation
specifications
Ordering specifications
Module specifications