FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

6. CONNECTION OF I/O UNITS TO
MACHINE INTERFACE
B63173EN/03
200
Power magnetics cabinet and machine operators panel
+24E
02
A
01
03
05
04
07
06
08
09
11
10
12
13
15
14
16
17
0V
+24E
B
DOC
0V
+24E
02
A
01
03
05
04
07
06
08
09
DOC
11
10
12
13
15
14
16
17
0V
+24E
B
DOC
0V
FSSB I/O module
CB155A CB156A
34pin flat cable connector
CB155A
Male
Female
CB156A
Male
Female
NOTE
1 +24E (output)
A voltage of 24 VDC supplied to the Power Mate main unit
is connected through a fuse an used for DI signals. Do not
connect an external 24 VDC output to this pin. Do not
connect is to DOC either.
2 DOC (external 24 VDC input)
An external voltage of 24 VDC should be supplied for DO
signals.
6.12.8