FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

7. CONNECTION TO FA NETWORKS
B63173EN/03
218
The radius of the cable
must be 70 mm or more.
10BASET
Twistedpair cable
Clamp
Ground plate
The Ethernet cable must be fastened by a cable clamp to prevent tension
being applied to the connector that connects the cable to the control unit
(RJ45) even if the Ethernet cable is pulled directly. This clamp is also
used to ground the cable shield.
CD38L
Pin No. Signal name Description
1 TX+ Send +
2 TX Send
3 RX+ Receive +
4 Not used
5 Not used
6 RX Receive
7 Not used
8 Not used
7.4.3
10 BaseT Connector