FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

8. CONNECTION TO SETTING AND DISPLAY UNIT
B63173EN/03
276
Details of display link cable J182
CA61 on detachable LCD/MDI
(DBM25S0001)
CA72 on relay panel
(DBM25S)
1FG 14
2 VDR 15 0V
3 VDG 16 0V
4 VDB 17 0V
5 VSYNC 18 0V
6 HSYNC 19 0V
7200V
8 TXD 21 0V
9 *TXD 22 RXD
10 23 *RXD
11 24
12 25
13
1FG 14
2 VDR 15 0V
3 VDG 16 0V
4 VDB 17 0V
5 VSYNC 18 0V
6 HSYNC 19 0V
7200V
8 TXD 21 0V
9 *TXD 22 RXD
10 23 *RXD
11 24
12 25
13
J182
CA72
RXD
*RXD
0V
TXD
*TXD
0V
Shell
VDR
0V
VDG
0V
VDB
0V
HSYNC
0V
VSYNC
0V
FG
22
23
21
8
9
20
2
15
3
16
4
17
6
19
5
18
1
Shield
22
23
21
8
9
20
2
15
3
16
4
17
6
19
5
18
1
RXD
*RXD
0V
TXD
*TXD
0V
VDR
0V
VDG
0V
VDB
0V
HSYNC
0V
VSYNC
0V
FG
#28AWG
#25AWG shielded
twisted pair
75 coaxial
cable
Recommended cable: A66L00010450 (#25AWG shielded twisted pair 2, 75 coaxial cable 5, common shield)
Standard outside diameter 11.4 mm (12 mm maximum) <Hitachi Cable, Ltd.>
Recommended connectors CA61 and CA72: DSUB 25pin (DBM25P) <Japan Aviation Electronics>
An appropriate case for the outside diameter of the cable used is required.
Recommended case: DBC4J11S2 <Japan Aviation Electronics>
The total length of cables J182 and J183 is 50 m maximum.