FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

B63173EN/03
8. CONNECTION TO SETTING AND DISPLAY UNIT
281
Details of video signal cable J185
CNC JA1
(PCREV20MDT)
CA72 on relay panel72
(DBM25S)
J185
1 VDR 11
2 0V 12 VSYNC
3 VDG 13
40V 140V
5 VDG 15
60V 160V
717
8 18 HSYNC
919
10 20
1FG 14
2 VDR 15 0V
3 VDG 16 0V
4 VDB 17 0V
5 VSYNC 18 0V
6 HSYNC 19 0V
7 20 (0V)
8 (TXD) 21 (0V)
9 (*TXD) 22 (RXD)
10 23 (*RXD)
11 24
12 25
13
VDR
0V
VDG
0V
VDB
0V
HSYNC
0V
VSYNC
0V
FG
VDR
0V
VDG
0V
VDB
0V
HSYNC
0V
VSYNC
0V
JA1
1
2
3
4
5
6
18
16
12
14
CA72
2
15
3
16
4
17
6
19
5
18
1
Shield
75
coaxial cable
Recommended cable: A66L00010371 (5conductor coaxial cable, common shield) <Hitachi Cable, Ltd.>
Recommended connector JA1: FI40B20S (solder type, 15 pins), case: FI20CV5 <Hirose Electric Co., Ltd.>
Recommended connector CA72: DBM25S, metal lock: D20418J9 <Japan Aviation Electronics>
The total length of cables J185 and J182 is 50 m maximum.
NOTE
Connect pin 1 (FG) of relay connector CA72 to the cabinet.