FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

B63173EN/03
8. CONNECTION TO SETTING AND DISPLAY UNIT
297
8) Safety precautions
To make the handy operators panel disconnectable, the handy
operators panel enable switch must be mounted on the connection
panel. When the handy operators panel is connected, but the handy
operators panel enable switch is set to DISCONNECT, the
emergency stop and deadman switches on the handy operators panel
are disabled. Therefore, when the handy operators panel is connected,
do not set the handy operators panel enable switch to
DISCONNECT. Put up a notice indicating this near the handy
operators panel enable switch.
CAUTION
1 While the handy operators panel is in use, do not set the
handy operators panel enable switch to DISCONNECT.
Otherwise, the emergency stop and deadman switches on
the handy operators panel will be disabled.
2 While the handy operators panel is in use, do not let anyone
else set the handy operators panel enable switch to
DISCONNECT. One way to accomplish this is to use a
handy operators panel with a key attached so that the user
of the handy operators panel can keep the key.
3 After the emergency stop switch on the handy operators
panel has been pressed, do not reset the emergency stop
by setting the handy operators panel enable switch to
DISCONNECT.
4 When the handy operators panel is not being used (the
handy operators panel enable switch is set to
DISCONNECT), remove the handy operators panel and
put it away so that no one may think that the emergency stop
and deadman switches on the handy operators panel are
effective.
Setting the handy operators panel enable switch to DISCONNECT
when the handy operators panel is connected causes the power to the
handy operators panel to be turned off, turning off the display on the
handy operators panel.

Leave a Reply