FANUC Power Mate i-MODEL H CONNECTION MANUAL (HARDWARE)

B63173EN/03
9. CONNECTION TO SERVO OR SPINDLE
321
Power to the separate detector interface unit should be supplied from an
external 24 VDC power supply. To the extended unit, if it exists, power
is supplied from the basic unit.
+24V
2
1
0V
3
CP11A
+24V (1)
0V (2)
Separate detector interface unit (basic)
24 VDC regulated
power supply
24 VDC +10%
Cable
CP11A
AMP JAPAN
11782883 (Housing)
11752185 (Contact)
External power supply
Select a connector
that matches the pin
layout of the external
power supply.
Recommended cable specification:
A02B0124K830 (5 m)
(The external power supply end of the cable is provided with M3
crimp terminals.)
External power supply
The 24 VDC input to CP11A can be output at CP11B for use in branching.
The connection of CP11B is identical to that of CP11A.
9.2.2
Connection of Power
Supply